– Dedicated 5 zones fire alarm system
– Simple fire alarm functionality
– Various test functions
– Self-diagnosis system
– Mis-operation inhibit function
– Built-in surge arrestor for power lines
– Back-up power supply (Ni-Cd battery)
– 220V, 50/60Hz for AC input
– 10 and 20 zones fire alarm system available
– Various test functions
– Self-diagnosis system
– Mis-operation inhibit function
– Built-in surge arrestor for power lines
– Built-in telephone system
– Fire zone indication by both zone plates and digital display
– 1,000 event log
– Functions programmable at site
– Back-up power supply (Ni-Cd battery)
– 220V, 50/60Hz for AC input
– 30 to 100 zones fire alarm system available
– Various test functions
– Self-diagnosis system
– Mis-operation inhibit function
– Built-in surge arrestor for power lines
– Built-in surge arrestor for power lines
– Built-in telephone system
– Fire zone indication by both zone plates and digital display
– 25 programmable dry contacts
– 10,000 event log
– Functions programmable at site
– Back-up power supply (Ni-Cd battery)
– 220V, 50/60Hz for AC input
– Dedicated to 5 or less 5 zones fire alarm system
– Zone plate indication with red LEDs
– Audible device (electronic buzzer) equipped
– 10 to 100 zones fire alarm system applicable
– Zone plate indication with red LEDs
– Built-in telephone system
– Audible device (electronic buzzer) equipped
– Very low profile
– 2-wire system
– 24VDC for rated operating voltage
– Small monitoring current of 45uA
– Remote indication circuit available (FDK246-X)
– Very low profile (28.7mm/1.13 inch only in height)
– 2-wire system
– Wide range input voltage 15.0 to 28.8VDC
– High air velocity rating
– LEDs for 360° Viewing
– Sensitivity check by flashing LED
– IP42
– Remote indication circuit available
– UL listed (UL268 7th Edition)
– Wide and high coverage within 100m distance
– Sensitivity drift compensation of contamination or a slight shift in the optical system
– Light synchronized system preventing false alarms
– Simple optical axis setting
– Optical remote test switch for easy maintenance
– 24VDC for rated operating voltage
– Low profile
– 2-wire system
– Rate-of-rise operates when the temperature increases 10°C (FDPJ106), 15°C (FDPJ206 series) per minute occurs
– Remote testing mechanism available (FDPJ206-D-T)
– Response lamp holding circuit available (FDPJ206-D-M)
– Remote indication circuit available (FDPJ206-D-X)
– 30VDC 75mA for contact ratings
– 65°C or 75°C operating temperatur
– 2-wire system
– Physical protector equipped
– Alarm response lamp (LED)
– Water proof type available (FDLJ906- DW-65, FDLJ106-DW-X75, FDLJ106- DW-S75)
– Remote indication circuit available (FDLJ106-DW-X75)
– Dry contact circuit available (FDLJ106- DW-S75)
– 30VDC 75mA for contact ratings (62mA for FDLJ106-DW-S75)