MKEG

Flame Detectors

[1] IR3 flame detector, PDCJ001-D

– Infrared three-wavelength flame detector (with testing function)
– Non explosion proof type
– 24VDC for rated operating voltage
– Dustproof and waterproof (equivalent to “IP66”)
– Horizontal and vertical 90° angle view for detection (the angle at which the monitoring distance is 1/2 to the front direction)
– Equipped with self-diagnosis function
– High sensitivity (33cm2 normal heptane flame detector at 60m front distance)
– Reliable fire detection CO2 resonance radiation principle, operation on flickering flame
– Approximately 3 seconds for delay time (changeable by setting)

[2] Addressable IR3 flame detector, FDCJ004-D

– Infrared three wavelength spot type flame detector(with testing function)
– Non explosion proof type
– 24VDC for rated operating voltage
– Dustproof and waterproof (equivalent to “IP66”)
– Equipped with self diagnosis function
– High sensitivity
– Reliable fire detection CO2 resonance radiation principle, operation on flickering flame
– Long monitoring range Max. 25m (50° from the center) to max. 45m (0° from the center)
– Wide viewing area 100° (50° in all directions from the center line of the detector downward to the floor)
– The Japanese standard approved product

[3] Conventional flame detector, FDCJ002-D-X

– Infrared type flame detector
– CO2 resonance radiation principle, operation on flickering flame
– 2-wire system
– 13 to 20m monitoring distance
– 100° angle view for detection
– With remote indication circuit
– 24VDC for rated operating voltage
– The Japanese standard approved product

– Infrared three-wavelength flame detector (with testing function)
– Explosion proof type Exde II CT5 (Body: Explosion proof type, Terminal: Increased safety)
– 24VDC for rated operating voltage – Dustproof and waterproof (equivalent to “IP66”)
– Horizontal and vertical 90° angle view for detection (the angle at which the monitoring distance is 1/2 to the front direction)
– Equipped with self-diagnosis function
– High sensitivity (33cm2 normal heptane flame detector at 60m front distance)
– Reliable fire detection CO2 resonance radiation principle, operation on flickering flame
– Approximately 3 seconds for delay time (changeable by setting)

PAPJ002-R-4/8/12L(-P) for PDCJ001-D

– 4, 8, and 12 zones or 75°C operating temper
– 2-wire system
– Physical protector equipped
– Alarm response lamp (LED)
– Water proof type available (FDLJ906- DW-65, FDLJ106-DW-X75, FDLJ106- DW-S75
– Remote indication circuit available (FDLJ106-DW-X75)
– Dry contact circuit available (FDLJ106- DW-S75)
– 100V#10%, 50/60Hz for AC input
– 30VDC 75mA for contact ratings (62mA for FDLJ106-DW-S75)
– Japanese notation

FPI012B-1L~5L-A, -D for PDCJ002-E

– 1 to 5 zones (IR3 flame detector 1 unit / zone)
– Wall mounting, Indoor type
– (FPI012B-1L~5L-A) 100V10%, 50/60Hz for AC input (FPI012B-1L~5L-D) 24V#10% for DC input
– Japanese notation