MKEG

Others

 Fire alarm bells – FBM01U-D, FBM023, FBM023-D, FBW013-EA

– Motor driven type alarm bell
– High sound output with low current consumption
– Low RFI noise
– Lead wire connection
– 24VDC for rated operating voltage
– Indoor, Outdoor type (FBM01U-D)
– Rainproof type available (FBWO13-EA)
– Polarized type available (FBM01U-D, FBM023-D)
– UL listed product available (FBM01U-D)

 Strobe/Horn, NEC3-24WR

– Low profile
– Field selectable candela options of 15, 30, 60, 75, and 110
– NAC synchronization feature with MK-G Addressable FACPs or dedicated modules
– 24VDC for rated operating voltage
– UL listed

 Strobe Light, S-24WR

– Low profile
– Field selectable candela options of 15, 30, 60, 75, and 110
– NAC synchronization feature with Nohmi Addressable FACPs or dedicated modules
– Instant voltage verification feature
– 24VDC for rated operating voltage
– UL listed

 Horn, EH-24R

– Low profile
– NAC synchronization feature with Nohmi Addressable FACPs or dedicated modules
– Instant voltage verification feature
– 24VDC for rated operating voltage
– UL listed

 Manual Push Button, FMMN, FMRN, FMBN series – FMMN102-U. FMMN102-UW.
FMMN202-U. FMRN102-U. FMBN102-U, FMBN102-UW

– Cutting-edge compact design
– Push-button-type
– Easy reset after operation
– Addressable and conventional types available
– 30VDC 500mA (FMMN & FMRN) for contact ratings
– Indoor and Outdoor types available
– Telecommunication means provided (except for FMMN202-U)
– Response lamp provided (except for FMMN202-U)

 Pull Station, FMM01U series – FMM01U-SK2, FMM01U-SK1

– Single or dual action pull down activation
– Key reset
– 30VDC 1A or 125VAC 1A for switch contact ratings
– Terminal connectors
– Gold plated SPST and contacts
– High-gloss enamel finish
– Plastic break rod
– UL listed

 

 FLPJ series – FLPJ002. FDPJ002-W. FLPJ004. FLPJ004-W

– Cutting-edge new design (FLPJ004, FLPJ004-W)
– Noticeable red color
– Low current and high durability
– Wide and high visibility
– Outdoor type available

 
 FLL series – FLL061A-B, FLL061-C

– White cover plate and red LED with translucence lamp cover
– Two sizes available (70mm x 115mm and 65mm x 88mm)
– 50mA maximum rated current

 
 FWLN series

– Three-in-one composition (location lamp, manual push button, alarm bell)
– Cutting-edge new design
– Addressable and conventional available
– Surface and recess mountings available
– Easy installation and maintenance
– Indoor / Outdoor type available

 Manual station, FMEJ202-RG

– Flame proof and explosion proof product
– Exde Il CT6 for explosion class and ignition grade
– Location lamp equipped
– Applicable to both indoor and outdoor uses
– 24VDC for rated operating voltage

 Fire alarm bell, EMB-6 DC24V

– Rain proof and explosion proof product
– Exd Il BT4 for explosion class and ignition grade
– 24VDC for rated operating voltage

 Location lamp, EC2B-110
– Exde Il CT6 for explosion class and ignition grade – 24V AC/DC rated operating voltage
 SLDJ004 series – SLDJ004-U-E, SLDJ004-U-M

– Latch type
– Electrical resetting type and manual resetting type available
– 24VDC for rated operating voltage

FZL116 series – FZL116-E-40L-T (40 terminals), FZL116-K1-80L-T (80 terminals), FZL116-K1-120L-T

– 60VDC or less for max. permissible circuit voltage
– DC or not more than 150kHz for frequency band
– Impulse protection performance
* In common mode – Between a line and ground
~ Initial max value 350V or less
~ Max. value during operation 20V or less
* In normal mode – Between any two lines
~ Initial max value 350V or less
~ Max. value during operation 20V or less
– 20kA for impulse current (at impulse current waveform of 80/20uS)
– Japanese notation

 UVS-05BN, UVS-06CN

– Battery type (UVS-05BN) 24VDC wiring type (UVS-06CN)
– Ultraviolet detector
– Indoor type
– High sensitivity detection distance of 4m (About 3cm lighter flame in front of the detector)
– Detection within 15 seconds
– Wide viewing area (60° above and below the horizontal surface of the sensor, 50° to the left and right from the vertical surface of the sensor)
– Multilingual voice alarm (Japanese, English, Chinese, Korean)
– Sound level of 80dB or more (at 1m in front of the sensor)

Protector for heat & smoke detectors, FZP012-L

Telephone hand set, SC-PA1
Detector tester for heat detector, HK-3
  • Body, pole, bag and adaptor
  • Heating Cartridge selling separately
Detector tester (Gas type) for smoke detector, FTGW001-Z
  • Test gas selling separately
Detector tester for flame detector, FTEJ001-P
  • Recess mounting box
  • Powered by four AA batteries
  • Test distance within 20cm
  • 0°C ~ 40°C ambient temperature (except dewfall)
  • Compatible with FDCJ002-D-X
Detector tester for IR3 flame detector, FTEJ002-P
  • Recess mounting box
  • Powered by four AA batteries
  • Test by closed range
  • 0°C ~ 40°C ambient temperature (except dewfall)
  • Compatible with FDCJ004-D, PDCJ001-D
Sensitivity measuring unit. FTDJ001-P
  • Powered by four AA batteries
  • 0°C ~ 40°C ambient temperature
Pole for tester, ZERJ002-15, 45, 60 & ZEAJ001
  • Three size available (1.5m, 4.5m, 6.0m)
  • Compatible with HK-3, FTGW001-Z, FTEJ001-P, FTEJ002-P